Cov txheej txheem txias txias ntawm Oasis Bingfeng CounterflowKaw -Circuit Cooling Tower
Cov txheej txheem txias ntawm lubcounterflow kaw -circuit cooling toweryog cov txheej txheem kub kub thiab huab hwm coj hloov pauv, nrog nws cov ntsiab lus tseem ceeb yog qhov ua kom pom tseeb ntawmkub pauvefficiency los ntawm countercurrent ntws ntawm huab cua thiab dej. Cov hauv qab no yog cov ncauj lus kom ntxaws txog kev ua kom txias:
Theem 1: Kub Hloov (Internal Circulation)
High - cov txheej txheem kub dej nkag mus rau hauv qhov kawkub pauvcoil system ntawm lub twj tso kua mis ncig
Thaum tshav kub kub yog ua los ntawm lub raj phab ntsa mus rau sab nraud
Cov coils siv cov khoom siv thermal conductivity siab (cov raj tooj liab lossis 304 stainless hlau raj), nrog rau cov thermal conductivity ntawm 401 W / m·K thiab 16 W / m·K feem.

Theem 2: Ua ntej-Coling Theem (Kev Ua Haujlwm Qhuav)
Axial kiv cua kos ambient cua los ntawm hauv qab
Cua ntws vertically upward hla lub sab nraud ntawm lubkub pauvcoils
Thaum huab cua kub qis dua qhov kub ntawm dej inlet, qhov ua kom txias ua ntej yog ua tiav los ntawm kev nkag siabkub pauv
Cov theem no tuaj yeem txo cov dej kub ntawm 3-8 degree, nyob ntawm:
Ambient qhuav- qhov kub thiab txias
Cua ceev
Thaum tshav kub kub pauvcheeb tsam

Theem 3: evaporative txias (Kev ua haujlwm ntub dej)
Thaum ambient kub nce los yog yuav tsum tau txias ntxiv, lub kaw lus activates cov tshuaj tsuag:
Dej zaj duab xis tsim
Txau cov twj tso kua mis sib npaug faib dej hla lub coil sab nraud
Ua ib zaj duab xis dej tas li 0.5-1mm tuab
Txau ceev tswj ntawm 0.05-0.12 m³ / (m·h)
Evaporative Thaum tshav kub kub Absorption
Airflow hla dej zaj duab xis nto txhawb dej evaporation
Dej evaporation absorbs latent cua sov ntawm vaporization (kwv yees li 2450 kJ / kg)
Cov txheej txheem no tuaj yeem tshem tawm 70-80% ntawm tag nrho cov cua sov
Counterflow Advantages
Cov huab cua txias tshaj plaws hu rau qhov chaw qis tshaj qhov hluav taws xob dej
Cov huab cua kub tshaj plaws hu rau qhov kub siab tshaj plaws inlet dej cheeb tsam
Khaws qhov kub siab tshaj qhov sib txawv thoob plaws

Theem 4: Sib sib zog nqus txias
Drift eliminators zoo rov qab cov dej tawg
Saturated humid cua yog tawm los ntawm sab saum toj
Ib nrab evaporation ntawm cov dej txau, nrog cov dej seem rov qab mus rau hauv lub thawv ntim khoom
Tsis siv neeg dej ntxiv system tswj cov dej theem sib npaug
Kev tswj qhov kub thiab txias ua tiav los ntawm kev tswj cov tshuaj tsuag dej ntim thiab cua ntws

Intelligent Control System
Tiag - lub sijhawm saib xyuas qhov ntsuas:
Inlet / qhov hluav taws xob dej kub (qhov tseeb ± 0.1 degree)
ambient kub thiab humidity
Txau dej conductivity
Cov cuab yeej ua haujlwm raws li txoj cai
Automatic hom switching:
Qhuav hom: ambient kub<25°C
Wet mode: ambient temperature >25℃los yog kub qhov sib txawv Hom sib xyaw: tsis siv neeg hloov kho raws li kev thauj khoom Thaum tshav kub kub pauvefficiency txhim kho los ntawm 30-40% piv rau crossflow tsim Qhov hluav taws xob dej kub tuaj yeem ncav cuag ambient ntub - qhov muag kub +3-5 degree Hneev taw txo qis dua 25% Kev siv hluav taws xob txo qis los ntawm 20-30% Hauv ib txoj haujlwm cog tshuaj, cov cuab yeej ua haujlwm nyob rau hauv cov xwm txheej ntawm 32℃ambient kub thiab 65% txheeb ze av noo: Inlet dej kub: 65 degree Qhov hluav taws xob dej kub: 33 degree Kub poob: 32 degree Kev siv dej: tsuas yog 0.5-1% ntawm cov dej ntim Kev siv hluav taws xob: 28% qis dua li cov tshuab cua txias Cov txheej txheem txias txias no ua kom cov cuab yeej ruaj khov ua haujlwm nyob rau hauv ntau yam kev ua haujlwm thaum ua tiav kev siv hluav taws xob thiab dej. Xa kev nug
Thermal Performance yam ntxwv

Cov ntaub ntawv thov tiag tiag