mwwXaiv lus

Cov txheej txheem txias txias ntawm Oasis Bingfeng Counterflow Kaw -Circuit Cooling Ntauwd

Nov 21, 2025

Tso lus

Cov txheej txheem txias txias ntawm Oasis Bingfeng CounterflowKaw -Circuit Cooling Tower

Cov txheej txheem txias ntawm lubcounterflow kaw -circuit cooling toweryog cov txheej txheem kub kub thiab huab hwm coj hloov pauv, nrog nws cov ntsiab lus tseem ceeb yog qhov ua kom pom tseeb ntawmkub pauvefficiency los ntawm countercurrent ntws ntawm huab cua thiab dej. Cov hauv qab no yog cov ncauj lus kom ntxaws txog kev ua kom txias:


Theem 1: Kub Hloov (Internal Circulation)

High - cov txheej txheem kub dej nkag mus rau hauv qhov kawkub pauvcoil system ntawm lub twj tso kua mis ncig

Thaum tshav kub kub yog ua los ntawm lub raj phab ntsa mus rau sab nraud

Cov coils siv cov khoom siv thermal conductivity siab (cov raj tooj liab lossis 304 stainless hlau raj), nrog rau cov thermal conductivity ntawm 401 W / m·K thiab 16 W / m·K feem.

蒸发式空冷器

Theem 2: Ua ntej-Coling Theem (Kev Ua Haujlwm Qhuav)

Axial kiv cua kos ambient cua los ntawm hauv qab

Cua ntws vertically upward hla lub sab nraud ntawm lubkub pauvcoils

Thaum huab cua kub qis dua qhov kub ntawm dej inlet, qhov ua kom txias ua ntej yog ua tiav los ntawm kev nkag siabkub pauv

Cov theem no tuaj yeem txo cov dej kub ntawm 3-8 degree, nyob ntawm:

Ambient qhuav- qhov kub thiab txias

Cua ceev

Thaum tshav kub kub pauvcheeb tsam

闭式凉水塔

Theem 3: evaporative txias (Kev ua haujlwm ntub dej)

Thaum ambient kub nce los yog yuav tsum tau txias ntxiv, lub kaw lus activates cov tshuaj tsuag:

Dej zaj duab xis tsim

Txau cov twj tso kua mis sib npaug faib dej hla lub coil sab nraud

Ua ib zaj duab xis dej tas li 0.5-1mm tuab

Txau ceev tswj ntawm 0.05-0.12 m³ / (m·h)

Evaporative Thaum tshav kub kub Absorption

Airflow hla dej zaj duab xis nto txhawb dej evaporation

Dej evaporation absorbs latent cua sov ntawm vaporization (kwv yees li 2450 kJ / kg)

Cov txheej txheem no tuaj yeem tshem tawm 70-80% ntawm tag nrho cov cua sov

Counterflow Advantages

Cov huab cua txias tshaj plaws hu rau qhov chaw qis tshaj qhov hluav taws xob dej

Cov huab cua kub tshaj plaws hu rau qhov kub siab tshaj plaws inlet dej cheeb tsam

Khaws qhov kub siab tshaj qhov sib txawv thoob plaws

蒸发冷

Theem 4: Sib sib zog nqus txias

Drift eliminators zoo rov qab cov dej tawg

Saturated humid cua yog tawm los ntawm sab saum toj

Ib nrab evaporation ntawm cov dej txau, nrog cov dej seem rov qab mus rau hauv lub thawv ntim khoom

Tsis siv neeg dej ntxiv system tswj cov dej theem sib npaug

Kev tswj qhov kub thiab txias ua tiav los ntawm kev tswj cov tshuaj tsuag dej ntim thiab cua ntws

逆流式闭式冷却塔降温


Intelligent Control System

Tiag - lub sijhawm saib xyuas qhov ntsuas:

Inlet / qhov hluav taws xob dej kub (qhov tseeb ± 0.1 degree)

ambient kub thiab humidity

Txau dej conductivity

Cov cuab yeej ua haujlwm raws li txoj cai

Automatic hom switching:

Qhuav hom: ambient kub<25°C

Wet mode: ambient temperature >25℃los yog kub qhov sib txawv

Hom sib xyaw: tsis siv neeg hloov kho raws li kev thauj khoom

闭式冷却塔智能调控


Thermal Performance yam ntxwv

Thaum tshav kub kub pauvefficiency txhim kho los ntawm 30-40% piv rau crossflow tsim

Qhov hluav taws xob dej kub tuaj yeem ncav cuag ambient ntub - qhov muag kub +3-5 degree

Hneev taw txo qis dua 25%

Kev siv hluav taws xob txo qis los ntawm 20-30%

逆流式闭式冷却塔


Cov ntaub ntawv thov tiag tiag

Hauv ib txoj haujlwm cog tshuaj, cov cuab yeej ua haujlwm nyob rau hauv cov xwm txheej ntawm 32℃ambient kub thiab 65% txheeb ze av noo:

Inlet dej kub: 65 degree

Qhov hluav taws xob dej kub: 33 degree

Kub poob: 32 degree

Kev siv dej: tsuas yog 0.5-1% ntawm cov dej ntim

Kev siv hluav taws xob: 28% qis dua li cov tshuab cua txias

Cov txheej txheem txias txias no ua kom cov cuab yeej ruaj khov ua haujlwm nyob rau hauv ntau yam kev ua haujlwm thaum ua tiav kev siv hluav taws xob thiab dej.

211

 

Xa kev nug