Cov roj hydraulic txias li cas?

Thaum lub sijhawm ua haujlwm hydraulic, cov roj hydraulic tsim hluav taws xob tseem ceeb vim muaj - siab txaus thiab kev sib txhuam ntawm cov neeg kho tshuab. Cov roj kub ntau dhau tuaj yeem ua rau txo cov viscosity, kev laus cov ntsaws ruaj ruaj, ua kom cov dej xau, thiab txawm tias cov khoom siv tsis ua haujlwm. Yog li, hydraulic roj yuav tsum tau ua kom txias thiab ruaj khov kom tswj tau qhov kev ua haujlwm ntawm qhov kub thiab txias.

Kauj Ruam 1: Siab-kub hydraulic roj nkag mus rau qhov kaw-circuit txias ntauwd

Thaum lub sijhawm ua haujlwm, cov roj hydraulic ua kom sov vim yog siab -siab ntws thiab kev sib txhuam (feem ntau ncav cuag 60-80℃lossis siab dua). Qhov siab - cov roj kub ntws los ntawm lub tank lossis cov kab rov qab tseem ceeb thiab yog lub zog los ntawm lub twj tso kua mis roj ua ntej xa ncaj qha mus rau qhov nkag ntawm qhov kaw-circuit txias ntauwd lub tshav kub pauv coil.

Nyob rau theem no, lub kauj muaj cov roj hydraulic ntshiab, tsis yog dej txias. Cov khoom siv coil feem ntau yog 304 lossis 316 stainless hlau kom ntseeg tau tias muaj kev sib raug zoo nrog cov roj hydraulic thiab corrosion kuj.

Kauj Ruam 2: Dual cua kub dissipation hauv lub pej thuam (tus txheej txheem tseem ceeb)

Thaum cov roj hydraulic nkag mus rau hauv lub kauj, kaw -circuit txias ntauwd pib nws txoj haujlwm txias, tso siab rau ob lub tshuab ua haujlwm ua ke:

1. Txau dej system

Cov dej los ntawm lub phiab hauv qab ntawm tus pej thuam yog pumped mus rau cov tshuaj tsuag cov kav dej saum lub kauj thiab tsis tu ncua sprayed tshaj sab nrauv ntawm lub kauj los ntawm cov sib npaug ntawm cov nozzles, zoo li los nag. Cov tshuaj tsuag dej hu rau phab ntsa kub coil thiab absorbs tshav kub hloov los ntawm cov roj hydraulic sab hauv.

Oasis Bingfeng Closed-Circuit Cooling Tower

2. Ntxuam qhov cua tshuab

Lub kiv cua nyob rau sab saum toj ntawm tus pej thuam pib ib txhij, kos ib lub ntim loj ntawm huab cua los ntawm sab qis lossis sab ntawm tus pej thuam. Cov huab cua ntws hla lub coil nto los ntawm hauv qab mus rau sab saum toj (los yog horizontally). Lub airflow tsis tsuas yog ncaj qha tshem tawm cov cua sov los ntawm lub coil nto, tab sis kuj accelerates lub evaporation ntawm cov dej tsuag. Raws li dej evaporates, nws absorbs ib tug loj npaum li cas ntawm latent tshav kub, uas yog ib feem ntawm cov txheej txheem txias.

Thaum tshav kub kub hloov txoj kev:Hydraulic roj (sab hauv coil) → Coil phab ntsa → Txau zaj duab xis dej → Cua (shaus los ntawm kiv cua)

Oasis Bingfeng Evaporative Condenser

Kauj Ruam 3:Txias hydraulic roj rov qab mus rau qhov system

Tom qab ntws los ntawm lub kauj thiab ua kom txias dual sab nraud, cov roj hydraulic kub tau txo qis (feem ntau mus rau qhov ntsuas kub ntawm 40-55 degree). Cov roj txias tawm ntawm lub qhov hluav taws xob coil thiab rov qab ncaj qha mus rau lub tank lossis lub ntsiab hydraulic Circuit Court, txuas ntxiv mus koom nrog cov khoom siv ua haujlwm, ua kom tiav lub voj voog txias.

Closed-Circuit Cooling Tower Manufacturer


Kauj Ruam 4: Txau cov dej ntws thiab rov ua kom tiav

Tom qab nqus cua sov, qee cov tshuaj tsuag dej evaporates, thaum cov seem poob rov qab rau hauv lub phiab, tau rov qab siv dua, thiab rov siv dua hauv lub voj voog tas li. Lub phiab yog txawm peem rau nrog ib tug tsis siv neeg pleev valve uas ntxiv dej tshiab thaum cov dej theem poob, kom ntseeg tau tas mus li thiab ruaj khov ua hauj lwm ntawm cov tshuaj tsuag system.

Air Cooler Manufacturer


Core Advantages of Oasis Bingfeng's DirectTxoj kev txias

Txoj kev ua kom txias ncaj qha siv hauv Oasis Bingfeng kaw- Circuit Court txias yees rau cov roj hydraulic (cov roj hydraulic ncaj qha nkag mus rau ntauwd lub kauj) muaj cov txiaj ntsig tshwj xeeb hauv qab no piv rau cov cua txias tsis ncaj lossis lwm yam kev ua kom txias txias:

1. Kev sib pauv cua sov siab tshaj plaws, ua kom txias ceev ceev

Lub hauv paus ntsiab lus tseem ceeb ntawm kev ua kom txias ncaj qha:

Cov roj hydraulic ntws ncaj qha los ntawm cov cua txias ntauwd lub tshav kub hloov pauv, thiab cov cua sov tau xa ncaj qha los ntawm phab ntsa coil mus rau cov tshuaj tsuag dej thiab cua, tsis muaj qhov nruab nrab nruab nrab kub poob.

Tshem tawm cov kauj ruam nruab nrab:

Tsis xav tau kev sib pauv cua sov thib ob los ntawm cov roj- dej kub exchanger, tsis txhob poob cua sov los ntawm cov kauj ruam nruab nrab.

Shortest tshav kub hloov txoj kev:

Roj → Coil phab ntsa → Txau dej / Cua, txoj kev luv tshaj plaws, cov lus teb ncaj qha tshaj plaws.

Txhim kho kev sib hloov hluav taws xob zoo:

15-20% siab dua piv rau indirect txias.

Tus neeg siv khoom tus nqi:

Cov roj kub poob qis dua nyob rau hauv tib lub sijhawm, cov lus teb raws sij hawm ntau dua, thiab cov khoom siv hydraulic nce mus txog kev ua haujlwm ruaj khov sai dua.


2. Ntau lub kaw lus compact, me dua hneev taw

Direct cooling tshem tawm cov roj-dej tshav kub exchanger thiab cais dej txias twj tso kua mis uas yuav tsum tau nyob rau hauv cov kev daws teeb meem indirect cooling, ua kom yooj yim rau lub system qauv:

Tsawg cov khoom xyaw:

Tsis xav tau ntxiv cov phaj kub hloov pauv, cov twj tso kua dej txias, lossis cov kav dej sib txuas.

Space -txuag:

Tag nrho cov hneev taw hneev taw txo los ntawm kwv yees li 30-40%.

Yooj yim installation:

Cov kav dej sib txuas yog yooj yim dua, ua kom lub sijhawm teeb tsa luv.

Tus neeg siv khoom tus nqi:

Kev ua kom txias ncaj qha yog qhov kev xaiv zoo tshaj plaws rau kev cob qhia nrog qhov chaw tsawg thiab cov khoom siv siab.

Air Cooler Manufacturer


3. Tus nqi peev qis dua, tus nqi siab dua -kev ua tau zoo

Los ntawm kev tshem tawm cov khoom siv hluav taws xob nruab nrab thiab cov kav dej sib txuas, cov kev daws teeb meem ncaj qha kom txo tau cov peev txheej pib:

Tus nqi ntawm cov khoom siv:

Tsis tas yuav yuav cov roj-dej tshav kub exchangers, dej txias twj tso kua mis, los yog txuam li qub thiab cov twj paj nruag.

Installation nqi:

Cov kav dej tsawg dua, tsawg dua welds, qis zog ua haujlwm thiab cov nqi khoom siv.

Tus nqi kho mob:

Cov khoom tsawg dua, tsawg dua cov ntsiab lus tsis ua haujlwm, txo cov haujlwm tu txhua hnub.

Tus neeg siv khoom tus nqi:

Ib tug tuag-casting enterprise txuag kwv yees li 25% nyob rau hauv thawj zaug peev uas siv ib tug ncaj qha txias tov piv rau indirect cua txias, nrog rau cov kev kho mob qis dua.


4. Cov lus teb ceev dua, tswj qhov kub thiab txias dua

Nrog ncaj qha cua txias,lub tshuab cua txiasua ncaj qha rau ntawm cov roj hydraulic nws tus kheej, tsis yog los ntawm dej raws li qhov nruab nrab nruab nrab:

Tsawg thermal inertia:

Tsis muaj lub voj voog dej txias nruab nrab, txo qhov ntsuas kub tswj lub sij hawm los ntawm kwv yees li 30-50%.

Ntau direct control:

Lub ntse ntsuas kub tswj xyuas cov roj kub ncaj qha, kho lub peev xwm txias hauv lub sijhawm.

Kev hloov pauv me me:

Tshem tawm qhov kub thiab txias los ntawm qhov nruab nrab ntawm lub voj voog dej, uas ua rau cov roj kub hloov pauv ntau dua.

Tus neeg siv khoom tus nqi:

Rau cov tshuab hydraulic nrog nquag pib / nres thiab cov kev hloov pauv tseem ceeb, cov cua txias ncaj qha teb sai dua, ua kom cov roj kub tsis tu ncua nyob rau hauv qhov kev ua haujlwm zoo.


5. Tshem tawm qhov kev pheej hmoo ntawm dej - sib tov roj

Hauv cov kev daws teeb meem tsis ncaj qha, cov roj -dej tshav kub exchanger ua rau muaj kev pheej hmoo tuaj yeem. Yog hais tias lub tshav kub exchanger puas lawm, cov dej txias tuaj yeem nkag mus rau cov roj hydraulic, ua rau muaj qhov tshwm sim loj:

Emulsification thiab degradation ntawm hydraulic roj

xeb thiab corrosion ntawm valve blocks thiab twj tso kua mis lub cev

Qhov system tsis ua haujlwm thiab kev tsim khoom kaw

Qhov zoo ntawm kev ua kom txias ncaj qha:

Cov roj hydraulic ua haujlwm tag nrho hauv qhov raug kaw -circuit cooling tower's coil, uas yog welded tag nrho thiab tau txais kev ntsuas nruj ua ntej tawm hauv lub hoobkas.

Txawm hais tias cov tshuaj tsuag dej sib cuag rau sab nraud ntawm lub kauj, nws tsuas yog ua haujlwm kom dissipate tshav kub - dej thiab roj tsis sib tov.

Ua tiav tshem tawm kev nyab xeeb kev nyab xeeb cuam tshuam nrog roj- dej kub exchanger leaks.

Tus neeg siv khoom tus nqi:

Kev ruaj ntseg hydraulic system ua haujlwm, roj lub neej ntev dua, thiab zam kev kho tus nqi siab vim muaj kev sib kis.

Oasis Bingfeng Closed-Circuit Cooling Tower


6. Oasis Bingfeng cov kev pabcuam tshwjxeeb rau kev ua kom txias

Txhawm rau kom muaj kev nyab xeeb thiab ua haujlwm tau zoo ntawm txoj kev ua kom txias ncaj qha, Oasis Bingfeng muab cov kev lees paub tshwj xeeb hauv qab no:

1. High-cov ntaub ntawv zoo

304/316 stainless hlau coils, sib xws nrog txhua hom roj hydraulic.

Kev tsim kho tiav welded, xau -dawb.

Corrosion-resistant, kev pab lub neej ntawm ntau tshaj 10 xyoo.

2. ntse tswj qhov kub thiab txias

Tiag -lub sij hawm roj ntsuas kub nrog ± 1℃raug.

Tsis siv neeg kho cov kiv cua ceev thiab cov tshuaj tsuag ntim kom haum rau lub nra.

Presettable roj kub ntau yam nrog tshaj - kub pib- tswb.

3. Roj- fouling tiv thaiv tsim

Optimized coil nto kho kom txo tau roj -fouling adhesion.

Uniform dej faib los ntawm cov tshuaj tsuag kom yaug cov txheej txheej txheej.

Configurable tu lub voj voog kom ncua sijhawm txij nkawm.

4. Kev tiv thaiv ntau yam kev nyab xeeb

Tsis siv neeg kaw kev tiv thaiv rau roj tshaj -kub.

Tiag -lub sij hawm coil siab xyuas nrog lub tswb tsis zoo.

Hom xwm txheej kub ntxhov thaum lub sij hawm hluav taws xob hluav taws xob kom tswj tau cov cua sov yooj yim.

530

 